ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module

Place of Origin: Refer to the product nameplate or origin documentation.
Brand Name: Nokia; specify whether original (OEM) or compatible
Certification: Subject to the specific certificates applicable to this model.
Model Number: ARHA 474801A
Minimum Order Quantity: 1 unit (recommended).
Price: Available upon request.
Packaging Details: Foam protection and export-grade cartons;
Delivery Time: Typically 3–7 business days for in-stock items.
Payment Terms: T/T (bank transfer) preferred; specific terms to be confirmed.
Supply Ability: Subject to current stock levels and order quantity.
Inquiry Now
Get A Quote
Specifications
Highlight Features

Flatpack S 24V/1000W Rectifier Module

,

241122.205 24V Rectifier Module

,

24V Telecom Power Rectifier

Type:
Power Module
Products Status:
Stock
Product Name:
241122.205
Shipping Term:
DHL,Fedex,UPS,EMS,AIR
Condition:
Brand New
Warranty:
Six Month
Product Description

  ELTEK Flatpack S 24V/1000W HE 241122.205 rectifier module

   

        Product Description:

ELTEK Flatpack S 24V/1000W HE 241122.205 rectifier module is used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.


Model 24/1000 HE
Part number 241122.205
INPUT DATA
Voltage (nominal range) 185 VAC/DC - 305 VAC / 300VDC
Voltage (operating range) 85 VAC/DC - 305 VAC / 300VDC
Frequency (nominal / range) 45 - 66 Hz / DC
Maximum current 5.9 ARMS
Power Factor > 0.99 at 50% load or more
Protection

Fuse

Shutdown above 305 VAC / 300 VDC

OUTPUT DATA
Voltage (default) 26.7 VDC
Voltage (adjustable range)

21 - 29 VD 1)

C

Max power, nominal input 1000 W
Max power, @ 85 VAC/DC 440 W
Max current 41.7 A (@VOUT < 24 VDC)
Current sharing ±5% of maximum current from 10 to 100% load
Static voltage regulation (10-100% load) ±0.5%
Dynamic voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Hold up time >20ms; output voltage > 21 VDC
Ripple < 150 mVPP , 30 MHz bandwidth


Protection

Blocking OR-ing Diode, Short circuit proof, Over voltage protection and High temperature protection
OTHER SPECIFICATIONS
Peak Efficiency 92.5 %
Isolation 3.0 kVAC - input and output, 1.5 kVAC - input earth, 0.5 kVDC - output earth
Alarms (Red LED) Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure
Warnings (Yellow LED) Rectifier in power de-rate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage
Normal (Green LED) Input and output ok
Potential alarm relay (normally closed) Opens on alarms and mains outage
MTBF (Telcordia SR-232 Iss.3 Meth. II Case L1) >1 975 044 (@ Tambient : 25 °C)
Operating temperature (5 - 95% RH non-cond.) - 40 - 85°C [-40 - 185°F ]
Max output power de-rates above temp / to 45°C [+113°F] / 400 W
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 72 x 41.5 x 217mm (2.83 x 1.63 x 8.54”) / < 850 g (1.9 lbs)
DESIGN STANDARDS
Electrical safety

EN 62368-1:2020+A11:2020, IEC 62368-1:2018, UL 62368-1:2019

IEC 60950-1:2013


EMC

EN 61000-6-1:2019, -6-2:2019, -6-3:2007 + A1:2011, -6-4:2019

IEC 61000-6-5:2015, FCC CFR 47 Part 15:2013

ETSI EN 300 386v2.2.0, EN50121-4:2016 + A1:2019, -5:2017 + A1:2019

Marine DNVGL-CG-0339, ABS PDA Certificate2)



Environment

ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)

EU 2015/863 (RoHS), 2012/19/EU (WEEE), IEC 63000:2018

Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised